Daikin furnace repair often involves more than the furnace: a two-stage valve, a variable-speed blower and sometimes a smart thermostat that talks to it. We repair these as part of our furnace repair in Toronto and GTA service, so this page covers what the maker says about its furnaces, the symptoms we see and how to prepare for a visit.
Key takeaways
- Daikin Industries began in 1924 in Osaka and agreed to buy Goodman in 2012.
- Daikin’s US page for the DM96VC lists two-stage heating, a variable-speed ECM blower and a self-diagnostic board.
- A smart thermostat that works with the furnace is part of the system we check.
- Our TSSA-certified gas technicians give a flat-rate price before work starts.
- Open 24/7 for no-heat calls in Toronto and the GTA.
Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.
On this page
- Daikin furnace repair means checking the whole system
- A short history of Daikin
- What Daikin lists for its DM96VC furnace
- Symptoms that call for Daikin furnace repair
- The Daikin One+ and your furnace
- Repairs we do on Daikin gas furnaces
- What to try, and what to leave alone
- Daikin furnace codes: E0, E3 and the rest on a DM96VC
- Daikin registration and paperwork
- Repair or replace a Daikin furnace
- Safety and what a visit involves
- Daikin furnace repair questions
Daikin furnace repair means checking the whole system
A modern Daikin furnace can be tied to its thermostat, so a heating complaint may start at the furnace, the blower or the thermostat connection. We test the call for heat from the wall to the burners, then the airflow after the flame lights.
That approach saves a part swap when the real problem is a setting, a loose connection or a dirty filter.
A short history of Daikin
Daikin Industries was founded in 1924, is headquartered in Osaka, Japan, and is listed on the Tokyo Stock Exchange. It agreed to buy Goodman Global in August 2012, and that its Goodman manufacturing was later consolidated at the Daikin Texas Technology Park in Waller, Texas, which opened in 2017.
In North America the residential arm is Daikin Comfort Technologies North America. Whether any particular Daikin furnace shares parts with another brand is not something our sources say, so we don’t claim it.
What Daikin lists for its DM96VC furnace
Daikin Comfort’s DM96VC page, a US site, lists up to 96% AFUE, a two-stage gas valve, a variable-speed ECM blower, a quiet two-speed inducer, a silicon nitride igniter, a self-diagnostic control board and compatibility with the Daikin One+ smart thermostat. These are the maker’s statements for that one model. Daikin’s home page also describes its furnaces as offering variable speed options.
We can’t confirm which Daikin furnaces are sold in Canada. If your furnace is a different model, the parts list will differ, which is why we confirm from the rating plate before ordering anything.
| Daikin lists | In plain terms | What a technician tests |
|---|---|---|
| Two-stage gas valve | Low heat most of the time, high heat in a cold snap | Stage switching, valve operation, pressure readings |
| Variable-speed ECM blower | Airflow changes with the heating stage | Motor, its control and the filter and duct restrictions |
| Quiet two-speed inducer | Pulls exhaust through the vent at two speeds | Inducer motor, pressure switch, vent pipes |
| Silicon nitride igniter | Lights burners with no constant pilot flame | Glow, resistance and sealing of the igniter |
Symptoms that call for Daikin furnace repair
These are the complaints that bring most two-stage, variable-speed furnaces to our attention. Any of them can have a simple cause, but a few point to a part that needs replacing.
- Heat that comes on but never gets the house warm in cold weather, which can mean the high stage isn’t engaging
- A blower that hums, speeds up and slows down oddly, or won’t start
- Burners that light and drop out after a few seconds
- A thermostat screen that goes dark or loses its link to the furnace
- A repeating light pattern on the control board and a furnace that has locked out
The Daikin One+ and your furnace
Daikin says the DM96VC is compatible with its Daikin One+ smart thermostat (US site). When the thermostat and furnace share a communicating link, a bad connection can look like a failed furnace. We test the wiring and settings as part of the diagnosis, and we don’t reconfigure a communicating system without your say-so.
Repairs we do on Daikin gas furnaces
The majority of repairs fall into a short list, and most can be done on the first visit once we know the part number from the rating plate. These are the jobs we do most often on a Daikin gas furnace.
- Hot surface igniter replacement after a glow test
- Flame sensor cleaning or replacement
- Inducer motor, pressure switch and vent-pipe faults
- Blower and ECM motor replacement, with a check of the filter and ducts
- Control board replacement after confirming the fault is not upstream
- Condensate trap and line cleaning on 90%+ furnaces
What to try, and what to leave alone
You can safely check the thermostat, the switch, the breaker and the filter before anyone arrives. Don’t open the burner compartment, touch wiring or relight anything, and stop at one reset, because repeated resets only repeat the same lockout.
- Set the thermostat to Heat and check its batteries if it takes them
- Confirm the furnace service switch and breaker are on
- Put in a clean filter and close the blower door
- Clear snow from the outdoor pipes by hand on a high-efficiency furnace
- Look through the door window for the board’s code and write it down
Daikin furnace codes: E0, E3 and the rest on a DM96VC
The DM96VC and DC96VC show a two-character code on the control board, and a steady “On” means all is well. Daikin prints the list in its DM96VC installation manual (opens in a new tab), page 49, with causes on pages 51 to 55. Other Daikin furnaces may use different codes.
If the furnace locks out on E0, the control resets itself after one hour. Record the code first, because the blower door has a switch that cuts power to the board when the door comes off.
| Code | What it means | What to do |
|---|---|---|
| On | Normal operation | No action needed |
| None (blank) | No power at the board: switch off, door switch open, fuse, breaker or a control fault | Make sure the furnace switch and breaker are on and the blower door is shut; then book a repair |
| E0 | Lockout after three failed ignition retries | Book a repair |
| E1 | Low stage pressure switch stuck closed as heating starts | Book a repair |
| E2 | Low stage pressure switch stuck open: blocked flue, intake or drain, a pinched hose or a weak inducer | Clear snow or ice from the outdoor pipes by hand; book a repair if it repeats |
| E3 | High limit open; the chart also lists the rollout limit, so overheating or flame rollout | Check the filter, then call a technician |
| E4 | Flame detected when there should be none | Call a technician |
| E6 | Low flame signal while the furnace keeps working | Book a repair |
| E7 | Igniter fault or improper grounding | Book a repair |
| E9 | High stage pressure switch stuck open, so only low heat | Check the outdoor pipes for snow, then book a repair |
| EF | Auxiliary switch open from high water in the air conditioning coil | Call a technician |
| b9 | Low indoor airflow | Replace a blocked filter and make sure every register is open |
Jot down the code and whether it showed at start-up or mid-cycle. A TSSA-certified gas technician from our team reads the board on arrival and tests the switch, sensor or motor behind the code before recommending a part.
Daikin registration and paperwork
Daikin’s warranty page invites owners to register a new system, and it states no deadline. Check the maker’s Canadian pages for the terms that apply to you, and keep your invoice and model details together.
Daikin’s home page also links a Canadian rebate centre. If you’re considering a cold-climate heat pump, see our rebates page.
Repair or replace a Daikin furnace
Repair when the fault is one part and the furnace is under about 15 years old; replace when it is near 20, or at any age if the heat exchanger is cracked.
| Age | A single failed part | A major failure |
|---|---|---|
| Under 10 years | Repair | Repair, then monitor |
| 10 to 15 years | Repair | Compare options |
| 15 to 20 years | Repair if reasonable | Lean toward replacement |
Safety and what a visit involves
If you smell gas, leave the house and call Enbridge Gas at 1-866-763-5427 from outside; for a CO alarm, get out and call 911. We are open 24/7 and send technicians day or night for no-heat calls.
We give a flat-rate price you approve before the repair, and our HVAC maintenance plan covers two tune-ups a year if you want to stay ahead of the next one. For a look at local service, see furnace repair in Mississauga, or Daikin’s residential site (opens in a new tab).
Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Daikin. Brand names are trademarks of their owners.
Daikin furnace repair questions
Is Daikin the same as Goodman?
Daikin agreed to buy Goodman Global in 2012, and Goodman Manufacturing is an independent subsidiary of Daikin Group. They are separate brand names, though. We can’t say whether any parts or factories are shared between Daikin and Goodman furnaces, so we work from the model number on your unit.
Does my Daikin furnace need a Daikin thermostat?
Not necessarily, and our sources don’t say. Daikin says the DM96VC is compatible with its Daikin One+ smart thermostat. If your furnace and thermostat were installed together as a communicating pair, tell the technician, and don’t swap the thermostat before the visit.
Why does my Daikin furnace blow cool air at the start of a cycle?
Many furnaces wait for the heat exchanger to warm before the blower speeds up, so a brief mild period is normal. If air stays cool, the burners may be dropping out, the filter may be blocked, or a limit switch may be tripping. Cold air that persists needs a technician.
What is a silicon nitride igniter?
Daikin lists a silicon nitride igniter on the DM96VC and says it removes the need for a constantly burning pilot. It is a hot surface igniter that glows to light the burners. Like other igniters it can wear out, and a technician tests its glow before replacing it.
Can you repair a two-stage Daikin furnace?
Yes. We test the low and high stage, the gas valve, the pressure switch and the blower. A furnace that runs only on one stage can have several possible causes, which is why we test in sequence instead of replacing the valve first.
What does a Daikin furnace flashing light mean?
On a DM96VC or DC96VC, a two-character code on the control board does the talking. E0 is a lockout after three failed ignition retries, and E3 means the high limit circuit opened, which a clogged filter can cause. The full list is in the table above, and other Daikin models may use different codes.
Do you offer 24/7 Daikin furnace repair?
Yes, we answer emergency calls 24/7 and send technicians out day or night when you have no heat. A TSSA-certified gas technician finds the fault and gives you a flat-rate price to approve. We cover Toronto, North York, Richmond Hill, Vaughan, Markham, Mississauga and Oakville.
Where can I find my Daikin furnace’s model number?
Look for the rating plate on the unit, usually inside the cabinet or on a side panel. We haven’t verified a Daikin-specific spot, so don’t take apart anything to find it. The model number is also on your installation paperwork, and the technician will read it on arrival.