Skip to content
Outdoor heat pump unit beside a brick house
Brands we repair

Lennox heat pump repair in Toronto

(647) 692-0819Open 24/7, day or night

A heat pump does the work of a furnace and an air conditioner, so when it fails in January you feel it fast. We handle Lennox heat pump repair for ducted systems and ductless mini-splits across Toronto and the GTA, and you approve a flat-rate price before work begins. Learn how these systems work on our heat pump installation in Toronto page.

Request a technician

Tell us what’s going on. We’ll call to confirm a time.

What do you need?
How soon? Optional
Add email, details or text updatesOptional

Or call (647) 692-0819Used only to book your visit. Privacy

Key takeaways

  • We repair Lennox ducted heat pumps and mini-splits in Toronto and the GTA.
  • Heat pumps run and defrost in winter, so ice on the outdoor unit is not always a fault.
  • Lennox’s US pages describe a ducted model for temperatures as low as -20°F.
  • Refrigerant work is done by 313A-certified mechanics, with leaks found before any recharge.
  • You approve a flat-rate price first, and we are open 24/7.

Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.

On this page
  1. Lennox heat pump repair in Toronto and the GTA
  2. What Lennox offers: ducted systems and mini-splits
  3. Lennox heat pump cold-weather claims, in the maker’s words
  4. Frost on the outdoor unit: normal or a fault?
  5. Common Lennox heat pump problems and fixes
  6. Apps, thermostats and controls on Lennox heat pumps
  7. Lennox heat pump error codes: the EL16KP1 diagnostic lights
  8. Safe checks before you call about your heat pump
  9. Lennox heat pump repair or replace: how to decide
  10. Warranty, registration and keeping service records
  11. Booking a repair, and no-heat nights
  12. Lennox heat pump repair questions

Lennox heat pump repair in Toronto and the GTA

We diagnose and repair Lennox heat pumps in Toronto and across the GTA, whether the unit stops heating, stops cooling or never seems to reach the temperature on the thermostat. Refrigerant and electrical work is done by qualified technicians. We service all major brands as an independent contractor.

What Lennox offers: ducted systems and mini-splits

Lennox International is based in Richardson, Texas, and sells both ducted heat pumps and mini-splits. All the Lennox pages we could load were US site pages, so we do not claim a given model is sold in Canada. Check the label on your own unit.

Lennox presents its mini-splits as “Lennox mini-splits Powered by Samsung”. Types listed include wall-mounted air handlers, a 2x2 ceiling mini-cassette and a high-static, ducted mini-split air handler. A mini-split has an outdoor unit plus one or more indoor units, which changes where we look for a fault.

Lennox heat pump cold-weather claims, in the maker’s words

Lennox states that its SL22KLV ducted heat pump delivers warm comfort in temperatures as low as -20°F, which is about -29°C. That is a maker’s marketing statement from a US page, not a promise from us, and real output drops as it gets colder.

Lennox also says the SL22KLV uses a variable-speed compressor with Electronic Refrigerant Injection, and that in colder temperatures the injection increases heating output efficiently. The full text is on the SL22KLV product page on Lennox’s US site.

Whatever the maker says, a heat pump in a Toronto winter works harder than one in a mild climate. When parts are tired or the charge is low, winter is when the problem shows up.

Frost on the outdoor unit: normal or a fault?

A light coating of frost on an outdoor heat pump is normal, because the unit periodically melts it in a defrost cycle. It is a problem when the unit stays buried in ice, when ice builds all the way up the cabinet, or when the house is cold while the unit sits frozen.

  • Brief steam or a change in sound during defrost is expected.
  • A thick shell of ice that does not clear points to a defrost or airflow fault.
  • Do not chip ice with a tool, since the coil fins damage easily.
  • Keep snow and drifts cleared back from the unit. If it sits low enough to get buried, ask us about raising it on a stand.
  • If the unit is frozen solid and the house is cold, switch to backup heat and call us.

Common Lennox heat pump problems and fixes

Heat pump faults mix electrical, refrigerant and control problems, and a good diagnosis separates them before parts are replaced. The table shows what a technician usually checks for each symptom.

Heat pump symptoms and the parts we check
What you noticeWhat we checkLikely cause
Blows cool air in heating modeReversing valve, refrigerant charge, defrost controlsValve, charge or defrost fault
Outdoor fan silent, unit humsCapacitor, contactor, fan motorWeak or failed electrical part
Runs constantly, house stays coldRefrigerant charge, coil, airflow, sizingLeak or restricted airflow
Mini-split indoor head leaking waterCondensate line, tilt of the head, filterBlocked drain
Mini-split will not respond to remotePower supply, wiring, control boardControl fault
Breaker trips on startCompressor, wiring, capacitorElectrical or compressor fault

Refrigerant is not consumed, so a low charge means a leak. We locate it before adding anything.

Apps, thermostats and controls on Lennox heat pumps

Lennox’s mini-split page says the SmartThings app allows users to remotely regulate temperature, adjust settings and receive real-time updates. For its ducted SL22KLV, Lennox cites digital communication features and recommends the Lennox S40 Smart Thermostat.

If a unit stops responding to the app or thermostat, we test the power, wiring and the unit itself, so a Wi-Fi drop is ruled in or out. We do not interpret error codes from memory. For one current Lennox model, the next section lists the official meanings, and the technician reads the unit on site.

Lennox heat pump error codes: the EL16KP1 diagnostic lights

These codes are from Lennox’s EL16KP1 installation instructions (opens in a new tab), which cover the Elite Series EL16KP1 heat pump for R-454B refrigerant. Its demand defrost control shows status, faults and lockouts with two lights, a red DS1 and a green DS2, by whether each is off, on or flashing slow or fast.

That control sits inside the outdoor unit, so a technician reads it. Each fault adds a strike, and 5 strikes on one code means a lockout. Lennox’s homeowner notes say frost below 45 °F (7 °C) is normal, a defrost cycle lasts 5 to 15 minutes, steam rising from the unit is normal, and the thermostat may bring on auxiliary heat during defrost. A light pattern names a part to test, not a diagnosis.

Demand defrost control lights on the Lennox EL16KP1 (DS2 green, DS1 red)
CodeWhat it meansWhat to do
Both lights OFFPower problem: no 24 V power at the demand defrost control, or the control has failedCall a technician
Simultaneous SLOW FlashNormal operation or standbyNo action needed
Alternating SLOW Flash5-minute anti-short cycle delay after power-up, a safety trip or the end of a thermostat callNo action needed
Simultaneous FAST FlashAmbient sensor problem; defrost falls back to a timer and the system still heats or coolsBook a repair
Alternating FAST FlashCoil sensor problem; the control won’t defrost, though the system still heats or coolsBook a repair
Both lights ONDemand defrost control failureCall a technician
Red SLOW Flash, green OFFLow pressure faultCall a technician
Red ON, green OFFLow pressure lockoutCall a technician
Green SLOW Flash, red OFFHigh pressure faultCall a technician
Green ON, red OFFHigh pressure lockoutCall a technician

Note the light pattern if a technician reads it out, and what the system was doing when it stopped. Our technicians read the lights on site and test the sensor, pressure switch or control they point to before replacing anything. Other Lennox models may use different controls, so tell us the model number.

Safe checks before you call about your heat pump

A few quick checks can save you a visit, and none of them involve opening the unit or touching refrigerant lines. If the checks do not help, call us before a small problem grows into a bigger one.

  • Confirm the thermostat is set to Heat or Cool, as you need, with a target that calls for it.
  • Check the breaker and the outdoor disconnect.
  • Clean or replace the filter, or clean the mini-split filters as the manual shows.
  • Clear snow, leaves and debris from around the outdoor unit.
  • Make sure indoor vents and mini-split louvres are not blocked.
  • Switch the system off for a few minutes, then back on once.

Lennox heat pump repair or replace: how to decide

A heat pump typically lasts about 15 years. Because it runs in both seasons, it logs more hours than an air conditioner alone, so its age and its repair history both count when you weigh a fix against a new unit.

Repair or replace a heat pump
SituationUsually better toWhy
Under 10 years, one electrical partRepairLow cost, long life left
About 15 years, compressor failurePrice replacementLargest repair on an aging system
Mini-split with a failed outdoor boardCompare repair and replacementDepends on parts and age
Old R-22 systemReplaceThe refrigerant is no longer produced

If you are thinking about a new system, programs change often. Read our rebates page and the Home Renovation Savings Program (opens in a new tab), since amounts depend on your home and current heating fuel.

Warranty, registration and keeping service records

We could not verify Canadian warranty or registration terms for Lennox heat pumps, so check Lennox’s Canadian warranty page and your install paperwork. Keep the invoice and serial number somewhere easy to find.

Our own repairs come with a written workmanship warranty. Regular maintenance helps a heat pump through both seasons, and our maintenance plan includes two tune-ups a year and priority booking.

Booking a repair, and no-heat nights

Booked visits come with a text and a two-hour arrival window. For Lennox heat pump repair on a freezing night, our line is open 24/7 and technicians go out day or night, with emergency calls ahead of the rest.

We serve Toronto, North York, Richmond Hill, Vaughan, Markham, Mississauga and Oakville. In North York, our North York service area page has local details.

Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Lennox. Brand names are trademarks of their owners.

FAQ

Lennox heat pump repair questions

Why is my Lennox heat pump blowing cold air in winter?

It may be in a defrost cycle, which is brief and normal. If the cool air continues, the cause could be a low refrigerant charge, a reversing valve fault, or a defrost control problem. Switch to backup heat if you have it and call us for a diagnosis.

Is ice on my Lennox heat pump normal?

A light frost that clears is normal. A thick, unmelted shell of ice, or a unit that stays frozen while the house cools down, is not. Do not chip at it, since the fins damage easily. Shut the unit off, use your backup heat and call us.

Do you repair Lennox mini-splits as well as ducted heat pumps?

Yes. Our Lennox heat pump repair covers both ductless mini-splits and ducted heat pumps. On its US site, Lennox presents its mini-splits as Powered by Samsung, with wall-mounted, ceiling mini-cassette and ducted air handler types. Tell us which kind you have so we bring the right test tools.

Does a Lennox heat pump work in Toronto winters?

Lennox states its SL22KLV ducted model delivers warm comfort in temperatures as low as -20°F, according to its US site. Output still falls as it gets colder, and many homes keep a furnace or backup heat. We can tell you what your unit is doing.

Can you repair my Lennox heat pump if it uses the SmartThings app?

Yes. Lennox says the SmartThings app lets users adjust settings remotely and get updates on its mini-splits. If the app and unit disagree, we test the power, wiring and the unit itself. A dropped Wi-Fi connection is checked first and ruled in or out.

What does a Lennox heat pump error code mean?

It tells you what the outdoor control detected. On the Lennox EL16KP1, a red light flashing slowly with the green light off is a low pressure fault, and both lights flashing slowly together is normal operation. Those lights sit on a control inside the outdoor unit, so a technician reads them. The table above lists each pattern for that model.

How long does a Lennox heat pump last?

A heat pump typically lasts about 15 years, though use and maintenance matter. It works in both seasons, so it can wear faster than an air conditioner alone. We tell you plainly whether a repair or a replacement makes more sense for your unit.

Should I turn off my Lennox heat pump when it ices over?

Yes, if ice keeps building or covers the coil. Switch the system off at the thermostat, leave the outdoor unit alone and don’t chip at the ice, since the coil fins damage easily. Light frost that clears during a defrost cycle is normal. Call us if the ice returns after a few hours.

Book a visit

Need Lennox heat pump repair? We’ll call you back to book.

Send the form or call. You’ll get a confirmed arrival window and a price before any work starts.

(647) 692-0819

Open 24/7, with technicians out day or night for no-heat and no-cooling emergencies

Request a technician

Tell us what’s going on. We’ll call to confirm a time.

What do you need?
How soon? Optional
Add an email or detailsOptional

Or call (647) 692-0819Used only to book your visit. Privacy