If your tank has a Bradford White rating plate and the hot water has stopped, Bradford White water heater repair is a call we take day or night across Toronto and the GTA. Our TSSA-certified gas technicians read what the gas valve is telling them, test the failed part and quote a flat price first. Want the bigger picture? See our water heater service page.
Key takeaways
- Our technicians repair Bradford White atmospheric, power vent, direct vent and power direct vent tanks.
- Bradford White’s Canadian manual explains its gas valve light patterns, summed up in our table below.
- TSSA-certified gas technicians, with a flat-rate price approved before work starts.
- Open 24/7 across Toronto, Vaughan, Mississauga and the rest of the GTA.
- A yearly flush and anode check helps keep sediment from building up in the tank.
Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.
On this page
- Who makes Bradford White, and what they sell
- Four ways a Bradford White gas tank vents
- Bradford White water heater flashing light codes
- Defender Safety System and a heater that will not stay lit
- Bradford White water heater repair: parts we replace most
- Hydrojet, sediment and why you still drain the tank
- Finding the age of your tank on the rating plate
- Before you book: steps you can try safely
- Bradford White water heater repair or a new tank?
- Rent or own: three questions to ask yourself
- If it leaks or you smell gas
- Booking a visit in Toronto, North York or Oakville
- Bradford White water heater repair questions
Who makes Bradford White, and what they sell
Bradford White describes itself as an American company that manufactures in the United States, with a history of more than 140 years. Its corporate site lists headquarters in Ambler, Pennsylvania, and plants in five states. It also names a Canadian headquarters, distribution centre and training facility in Halton Hills, Ontario.
Residential lines include gas and electric tanks, heat pump, tankless, indirect water heaters and boilers. This page deals with tank repair.
Four ways a Bradford White gas tank vents
The maker sorts its gas tanks into four types: atmospheric vent, power vent, direct vent and power direct vent. The type tells us whether to look at a chimney, a blower, an outside-air pipe, or a combination of those.
| Vent type | How it vents | What we check first |
|---|---|---|
| Atmospheric Vent | Naturally vented | Draft, flue pipe, backdrafting |
| Power Vent | Blower vents exhaust horizontally | Blower, pressure switch, vent run |
| Direct Vent | Sealed, vented outdoors | Intake and exhaust terminations |
| Power Direct Vent | Blower plus sealed vent | Blower, both pipes, condensate if present |
Bradford White water heater flashing light codes
These patterns come from Bradford White’s Canadian installation and operation manual for its atmospheric vent gas tanks, RG models such as RG140T6N and RG240T6N with the ICON System gas control. The status light is on the gas control. The manual gives separate charts for the Resideo V1, Resideo V2 and SIT versions of that control, so a pattern can mean slightly different things on each one.
On the Resideo V2, a green flash every four seconds or every second is normal. Yellow means two flashes, and red marks four or five flashes, or a solid light while the control shuts down. The full charts are on pages 23 to 25 of Bradford White’s Canadian atmospheric vent manual (opens in a new tab).
| Code | What it means | What to do |
|---|---|---|
| Light off | Pilot is off, so the control has no power | Relight by following the lighting label on the tank. If it will not stay lit, book a repair |
| One flash, then a pause (every three or four seconds) | Pilot is lit and the burner is off: the tank is at temperature or the knob is at PILOT. Not an error | Nothing |
| Two quick flashes and a pause (Resideo V1), or one flash every second | Calling for heat with the burner on. Not an error | Nothing |
| Light on solid | The knob was recently turned to OFF and the control is shutting down. Not an error | Wait until the light goes out before relighting |
| Two flashes and three second pause | Weak pilot flame or low thermopile voltage, so the main burner will not come on | Book a repair |
| Three flashes and three second pause (Resideo V1) | Insufficient water heating | Book a repair |
| Four flashes and three second pause | Tank temperature too high: the temperature cut-out limit was reached and the heater shut down | Book a repair |
| Five flashes and three second pause | Resideo V1: temperature sensor fault. Resideo V2 and SIT: electronics, sensor or gas valve fault | Book a repair |
| Six flashes and three second pause (Resideo V1) | Water leak detected by the accessory module, on models that have one | Look for water in the drain pan, then book a repair |
| Seven flashes and three second pause (Resideo V1) | Gas valve electronic fault | Book a repair |
| Eight flashes and three second pause (Resideo V1) | False pilot flame present; the manual’s first suspect is a pilot valve stuck open | Call a technician |
Count the flashes over a few cycles and write the pattern down, with the colour if your light has one. Our TSSA-certified gas technicians check the pattern on site and test the part it points to before a new gas valve or sensor goes in.
Defender Safety System and a heater that will not stay lit
The Defender Safety System is the maker’s name for its flammable vapour ignition resistant design, with a ScreenLok flame arrestor. When a tank with this design will not stay lit, a clogged intake or arrestor screen is one thing a technician checks.
Our job is to find out why the heater stopped, which might be a dirty screen, a blocked air intake, or a real fault.
A blocked screen
A basement with a dryer, pet hair or renovation dust can clog an air intake over time. Cleaning it is simple, but only after we confirm that nothing else is wrong.
Bradford White water heater repair: parts we replace most
Most calls end with one of a few parts: a thermocouple or flame sensor, a gas valve, an igniter, a blower or pressure switch on a power vent model, or a worn anode rod. We test before we replace, so you are quoted for the part that actually failed.
- Thermocouple or flame sensor when the flame drops out after lighting
- Igniter on electronic-ignition tanks that click or glow but never light
- Gas control valve, replaced only after testing confirms it has failed
- Blower or pressure switch on power vent and power direct vent units
- Anode rod when the water smells or the tank is a few years in
Hydrojet, sediment and why you still drain the tank
Bradford White’s Hydrojet system reduces sediment buildup but, in the maker’s words, does not replace the need to periodically drain your tank. The FAQ adds that water heaters do benefit from periodic maintenance, ideally done by a plumbing professional.
A flush takes the sediment out before it bakes onto the bottom of the tank. Pair it with an anode check and ask about our maintenance plan.
Finding the age of your tank on the rating plate
Your model and serial numbers are on the rating plate on the water heater. Bradford White says the first two characters of the serial number represent the year and month of manufacture.
The part of the maker’s FAQ we reviewed does not give the letter-to-month key, so we will not translate a serial number here. Your install receipt or a quick look at the tank’s condition tells us more about age than a guess would.
Before you book: steps you can try safely
A short check often explains a heater that suddenly went cold. Do these only if there is no smell of gas, and stop at any point where you feel unsure.
- Look at the gas valve lights and write down what they do
- Confirm the gas shut-off to the tank is open
- On a power vent or power direct vent model, check the plug and breaker
- Look around the base for water and note whether it is from the tank or a fitting
Bradford White water heater repair or a new tank?
Fix the heater when the tank is sound and the failure is a single part. Replace it when the tank body leaks or it is well past ten years. A gas tank typically lasts 8 to 12 years, so a 12-year-old tank with a failed valve is a close call we will walk through with you.
| Situation | Lean toward |
|---|---|
| Tank under 8 years, one failed part | Repair |
| Tank 8 to 12 years, major part failed | Compare quotes |
| Water leaking from the tank shell | Replace |
| Repeated lockouts with a clean vent | Diagnose, then decide |
Rent or own: three questions to ask yourself
A tank you rent and a tank you own differ in what you carry yourself. Ask how long you plan to stay in the home, whether you prefer a fixed monthly cost or a one-time purchase, and whether you want to choose who services the heater. We say nothing about rental companies, so check your own agreement.
If it leaks or you smell gas
For a leak, shut the cold water valve on top of the tank, then call us. A gas smell is different: get out, and call Enbridge Gas on 1-866-763-5427 from outside the house.
An alarm from a carbon monoxide detector means everyone leaves and you call 911. The Ontario carbon monoxide guidance (opens in a new tab) explains why every home with a gas appliance needs working alarms.
Booking a visit in Toronto, North York or Oakville
Call and we book a two-hour window, then text you before we arrive. You get a flat-rate price to approve before work starts, and a written workmanship warranty on the repair. Calls for Bradford White water heater repair with no hot water are answered 24/7.
We also work in Richmond Hill, Vaughan, Markham and Mississauga. Our Oakville page has local details.
Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Bradford White. Brand names are trademarks of their owners.
Bradford White water heater repair questions
What do the flashing lights on my Bradford White gas valve mean?
It depends on the pattern and on which ICON control your tank has. Per Bradford White’s Canadian manual for atmospheric vent tanks, one flash every three or four seconds, or once a second, is normal. Two flashes mean a weak pilot or low thermopile voltage, and four flashes mean the tank got too hot and shut down. Count the flashes, check the table above and book a repair for any fault pattern.
Where is the model and serial number on a Bradford White tank?
The maker says both are on the rating plate on the water heater. Take a photo of it before you call, since the plate can be hard to read behind the tank. Keep that photo with your install paperwork so you have the details for any warranty question.
Can you tell the age of my tank from the serial number?
Partly. Bradford White says the first two characters of the serial number represent the year and month of manufacture, but it does not publish the letter-to-month key in the part of its FAQ we reviewed. We will not guess. Your receipt or install date is the safer record of age.
My heater went out after I cleaned the basement. Why?
Dust and lint can clog the air intake or flame arrestor screen on a Defender-equipped tank. Do not poke at it. A technician can clean the screen, confirm the burner area is clear and check the vent before the heater is put back on.
Is draining the tank still needed with a Hydrojet system?
Yes. Bradford White states that the Hydrojet system reduces sediment buildup but does not replace the need to periodically drain your tank. Its FAQ says periodic maintenance should be done by a plumbing professional. On our visits that means a flush plus a check of the anode rod and venting.
Do you repair power direct vent models?
Yes, along with atmospheric, power vent and direct vent models. A power direct vent tank combines a blower with sealed intake and exhaust pipes, so we check the blower, pressure switch and both pipe terminations. Gas work is done by TSSA-certified technicians.
Is the repair covered by my warranty?
Possibly. Bradford White has a Warranty Center and a Canada contact page, and those are the places to confirm coverage with your serial number. We cannot do warranty work on the maker’s behalf, but we can tell you exactly what failed so you have the facts when you ask.
Need Bradford White water heater repair? We’ll call you back to book.
Send the form or call. You’ll get a confirmed arrival window and a price before any work starts.
Open 24/7, with technicians out day or night for no-heat and no-cooling emergencies